Total Hydransafe HFC 146
Total Hydransafe HFC 146 Biodegradable fire resistant hydraulic fluid.
- HYDRANSAFE HFDU 46 is recommended for hydraulic equipment operating in
locations comprising a fire risk such as iron and steel works (coking plants, blast
furnaces, continuous casting), mines, etc… - The use of HYDRANSAFE HFDU 46 lessens the serious risks presented by recourse to
a mineral oil on the occasion of rupture of a hose or when a leak gives rise to oil mist, in
the immediate vicinity of a flame, a part in the process of melting or a switch cupboard. - Thanks to its biodegradability, HYDRANSAFE HFDU 46 is especially recommended
when there is a possibility of water contamination: offshore, mines.
Total Hydransafe HFC 146 Product Advantages:
- Considerable fire resistance properties.
- High flash point and high spontaneous ignition temperature.
- Protection against wear and therefore a longer service life of the hydraulic components.
- Very good anti-corrosion properties.
- A very high natural viscosity index guarantees a viscosity constantly adapted to the temperature range in which the fluid must be used.
- Low pour-point provides good performances at low temperatures.
- Biodegradable.
- Limit temperature of use to 120°C.
TYPICAL CHARACTERISTICS | METHODS | UNITS | Value |
Density at 15°C
|
ISO 3675 | kg/m3 | 920 |
Kinematic viscosity at – 20°C
|
ISO 3104 | mm²/s | 1580 |
Kinematic viscosity at 40°C
|
ISO 3104 | mm²/s | 47.5 |
Kinematic viscosity at 100°C
|
ISO 3104 | mm²/s | 9.35 |
Viscosity index
|
ISO 2909 | – | 185 |
Air release at 50°C
|
ISO 9120 | min | 4 |
Foaming seq.1
|
ISO 6247 | ml/ml | < 50/0 |
Pour-point
|
ISO 3016 | ° C | – 42 |
Flash point V.O.
|
ISO 2592 | ° C | 310 |
Fire point
|
ISO 2592 | ° C | 358 |
Auto ignition temperature
|
ASTM 2155 | ° C | > 420 |
Biodegradability | OECD 301B | – | Ultimately biodegradable |
- ISO 6743/4 HFDU
- ISO 12922
- FACTORY MUTUAL in accordance with FM Approval Standard 6930 – “Flammability
classification of Industrial Fluids”.
Before using the product, the vehicle’s maintenance guide should be checked. The product should not be stored at temperatures over 60°C. It should be kept away from sunlight, intense cold and extreme temperature fluctuations. If possible, the packaging should not be exposed to the elements. Otherwise, the drums should be laid horizontally to avoid any contamination from water and to prevent the product’s label from rubbing off.