Total Azolla DZF 32
VISCOSITY - ISO 32
Total Azolla DZF 32 Detergent anti-wear hydraulic oils.
Total Azolla DZF 32 Detergent anti-wear hydraulic oils.
- Any hydraulic circuits where significant amounts of water are unavoidably introduced and when it is impossible to drain off the water (for instance on circuits that work around the clock).
- Any hydraulic circuits working under loaded conditions: lubrication of stamping presses for example (Müller Weingarten approval).
- Any hydraulic circuits are subjected to high levels of pollution.
Total Azolla DZF 32 Detergent anti-wear hydraulic oils Product Advantages:
- Detergent characteristics allow the fluid to absorb large quantities of water while preserving its properties.
- Detergent/Dispersant characteristics keeping the hydraulic system clean.
- High thermal stability gives the fluid good resistance at high operating temperatures.
- Excellent antiwear capacity ensuring an extended lifetime of product.
- Excellent level of resistance to foaming (silicon-free defoamer) together with rapid air release.
- Specially formulated to provide good filterability even in the presence of high water content.
- Protection against rust and corrosion.
TYPICAL CHARACTERISTICS | METHODS | UNITS | AZOLLA DZF 32 |
Density at 15 °C | ISO 3104 | kg/m³ | 875 |
Kinematic viscosity at 40 °C
|
ISO 3104 | mm²/s | 32 |
Kinematic viscosity at 100 °C
|
ISO 3104 | mm²/s | 5.5 |
Viscosity index | ISO 2909 | – | 102 |
Cleveland flash point OC | ISO 2592 | ℃ | 210 |
Pour point | ISO 3016 | ℃ | – 33 |
FZG test (A/8, 3/90), damage level | DIN 51 354 | Stage | -12 |
Brügger EP test | – | N/mm2 | – |
ISO 6743-4 HM
DIN 51 524 p 2, HLP-D (Detergent properties)
MAN N 698 H-LPD
MÜLLER WEINGARTEN
Before using the product, the vehicle’s maintenance guide should be checked. The product should not be stored at temperatures over 60°C. It should be kept away from sunlight, intense cold and extreme temperature fluctuations. If possible, the packaging should not be exposed to the elements. Otherwise, the drums should be laid horizontally to avoid any contamination from water and to prevent the product’s label from rubbing off.