Total Lunaria SH 46
VISCOSITY - ISO 46
Total Lunaria SH 46 Refrigeration Compressor Oil
Full-synthetic PAO-based oil for ammonia (R 717) refrigerating compressors.
- Lubrication of refrigerating compressors (reciprocating and screw) using ammonia as a refrigerant.
- PAO (polyalphaolefin) base oils to improve oil drain interval and ensure good performances even at very low temperatures.
- Field of application: evaporator temperature down to -50°C.
Total Lunaria SH 46 Refrigeration Compressor Oil Product Advantages:
- High resistance to oxidation in the presence of ammonia. Synthetic base oils and activation systems are specially selected to avoid the formation of black sludges (reaction between oil and ammonia).
- Low pour point, eliminating the risk of any residual lubricant freezing in the evaporator, thereby providing excellent heat exchange.
- Very high flash point given the low volatility of LUNARIA SH oils: oil consumption is reduced by 30 to 50 % compared with conventional oils.
- Good compatibility with common elastomers (chloroprene, NBR….).
- Warning: storage must be done in order to avoid the presence of water within the oil. Indeed, water could block the evaporator.
TYPICAL CHARACTERISTICS | METHODS | UNITS | Value |
Density at 15°C | ISO 3675 | kg/m³ | 830 |
Viscosity at 40°C
|
ISO 3104
|
mm²/s | 46 |
Viscosity at 100°C
|
ISO 3104
|
mm²/s | 7.8 |
Pour point | ISO 3016 | °C | -60 |
Flash point (open cup) | ISO 2592 | °C | 268 |
Before using the product, the vehicle’s maintenance guide should be checked. Oil changes should be carried out in accordance with the manufacturer’s recommendations. The product should not be stored at temperatures over 60°C. It should be kept away from sunlight, intense cold and extreme temperature fluctuations. If possible, the packaging should not be exposed to the elements. Otherwise, the drums should be laid horizontally in order to avoid any contamination from water and to prevent the product’s label from rubbing off.
All packages should be stored under cover. Where outside storage is unavoidable drums should be laid horizontally to avoid the possible ingress of water and damage to drum markings. Products should not be stored above 60°C, or exposed to hot sun or freezing conditions.