Total Equivis XLT 32
VISCOSITY - ISO 32
Total Equivis XLT 32 Ashless Mineral Hydraulic Fluid
EQUIVIS XLT is a hydraulic fluid designed for outdoor equipment operating under extremely low temperatures. The very high viscosity index of EQUIVIS XLT extends the temperature operating window of the hydraulic systems.
Total Equivis XLT 32 Ashless Mineral Hydraulic Fluid Product Advantages:
- The low cold temperature viscosity is limiting the cavitation issues during the start-up operations. With this low viscosity level, the hydraulic system can be fully operable immediately after the start-up.
- Good shear stability ensures the high-temperature lubricating film thickness and the hydraulic pump efficiency during all the fluid life.
- Ashless formulation offers a very high oxidation stability, reducing deposits and varnish formation and allowing extended drain intervals.
- Good wear, rust and corrosion protection of the material.
- Excellent air release behaviour.
TYPICAL CHARACTERISTICS | METHODS | UNITS | Value |
Appearance | Visual | – | Clear |
Density at 15 °C | ASTM D 4052 | – | 854 |
Kinematic Viscosity at 40 °C
|
ASTM D 445 | mm²/s | 32 |
Kinematic Viscosity at 100 °C | ASTM D 445 | mm²/s | 10.7 |
Kinematic Viscosity at -40 ℃ | ASTM D 445 | mm²/s | 1200 |
Viscosity Index | ASTM D 2270 | 350 | |
Flash point Cleveland | ASTM D 92 | °C | 110 |
Pour point | ASTM D 97 | °C | -51 |
4 balls wear | ASTM D 4172 | mm | 0,44 |
FZG A/8,3/90 | DIN 51 354/2 | stage | 10 |
Before using the product, the vehicle’s maintenance guide should be checked. Oil changes should be carried out in accordance with the manufacturer’s recommendations. The product should not be stored at temperatures over 60°C. It should be kept away from sunlight, intense cold and extreme temperature fluctuations. If possible, the packaging should not be exposed to the elements. Otherwise, the drums should be laid horizontally in order to avoid any contamination from water and to prevent the product’s label from rubbing off.
All packages should be stored under cover. Where outside storage is unavoidable drums should be laid horizontally to avoid the possible ingress of water and damage to drum markings. Products should not be stored above 60°C, or exposed to hot sun or freezing conditions.